Page not found

Search results

  1. Decks

    Community Development | Page

    PERPENDICULAR TO JOIST 16” O.C. / 24”O.C. FOR SP 5/4 AND 2X4 AT 45 DEGRESS TO JOIST 12” O.C. 2X6 24” O.C. ... 2- 12d nails are recommended on nominal 2-inch decking. 10d nails are recommended for 5/4" ... where spans do not exceed 16" o.c. (12” o.c. when installed diagonally to joists). Southern pine ...

  2. Capital Improvements: Street Reconstruction Plan

    Engineering / Public Works | Page

    2017-2021 to identify potential street reconstruction projects and their funding sources. The Plan is ... included for the years 2017-2021 are proposed projects and will be evaluated during budget cycles. In light ... Utilities (1st Street SW, 12th Avenue SW, 11th Avenue SW and 10th Avenue SW) City Project 2015-1 January 9, ...

  3. 2023 Adopted Levy and Tax Rate

    Finance | Page

    Levy 2020 Levy 2021 Levy 2022 Levy Payable 2019 Payable 2020 Payable 2021 Payable 2022 Payable 2023 ... $12,549,104 CERTIFIED LEVY 8,603,265 Less:- Abatement Levy- Less: TIF Captured tax increment (416,980) Fiscal ... 2019 8,329,612 6,937,752 80.847 2.443 83.290 2020 8,475,628 7,073,543 81.094 2.363 83.457 2021 ...

  4. Footings, Foundations & Slabs

    Community Development | Page

    extend 12 inches below undisturbed ground (R403.1.4) The top surface of footings must be level. The ... Conventional light-frame construction 1-story 12 12 12 2-story 15 12 12 3-story 23 17 12 4-inch brick veneer ... over light frame or 8-inch hollow concrete masonry 1-story 12 12 12 2-story 21 16 12 3-story 32 24 16- ...

  5. City Council Regular Meeting

    City Council | Calendar Event | 07/27/15 04:00pm

    4,052 10, 164 14, 399 5, 487 PERA 1, 708 1, 441 1, 723 1, 782 1, 862 876 FICA 12, 545 12, 782 12, 910 ... 12, 732 13, 467 5, 871 Fire Relief-City contribution 5, 000 5, 000 5, 000 5, 000 5, 000 Fire ... 365 Dental 141 118 164 Unemployment Workers Compensation 26,482 23, 682 19,014 28,652 24, 000 12 ...

  6. The Value of Trees

    Public Utilities | Page

    years the savings will be nearly 12%." —Dr. E. Greg McPherson, Center for Urban Forest Research ... of the tree (but not touching the trunk). Water the tree generously every week or 10 days during the ...

  7. Garages: One Story

    Community Development | Page

    angle not to exceed 60 degrees or less than 45 degrees.  4X8 wood structural panel sheathing not less ... must be attached with a minimum of 6d nails at 12 inches on center.  4X8 structural fiberboard ... 2-2X6 1 3-8 2-2X6 1 3-3 2-2X6 1 5-4 2-2X8 2 5-7 2-2X10 2 5-0 2-2X10 2 6-6 2-2X10 2 6-6 2-2X12 2 5-10 ...

  8. Fasteners

    Community Development | Page

    12 gauge shank with a minimum 3/8” diameter head and of a length to penetrate through the roofing ... a minimum of 5/8 inch. 1/2 “ Nails: 13 gage, 1 3/8” long, 19/64” head; 0.098 diameter, 1 ¼” long, annular- ... 6 12 19/32 – 1 8d common nail 6 12 1 1/8 – 1 ¼ 10d common nail or 8d deformed nail 6 12 a. All nails ...

  9. City Council Regular Meeting

    City Council | Calendar Event | 05/12/14 04:00pm

    3 Printed on 5/ 9/2014 City Council Meeting Agenda Full Detail May 12, 2014 5: 45 GOLF COURSE PM 19. 14-0474 ... Meeting with Agenda and Minutes Monday, May 12, 2014- 4:00pm Work Session Agenda ... citycouncil_agenda_2014-05-12.pdf Image Slideshow Display Contact Info Block Web Page Calendar Event Menu Settings City Council ...

  10. Complete Application Packet: Off-sale

    Administration | Page

    of twelve (12) months from the date of signature. ... This authorization shall be valid for a period of twelve (12) months from the date of signature. ... Background Check form Fillable PDF 4. MN Worker's Comp Fillable PDF Check Box11: Check Box12: Check ...

Pages