Page not found

Search results

  1. Decks

    Community Development | Page

    2- 12d nails are recommended on nominal 2-inch decking. 10d nails are recommended for 5/4" ... where spans do not exceed 16" o.c. (12” o.c. when installed diagonally to joists). Southern pine ... JOIST 12” O.C. FOOTINGS Call Gopher State One Call for utility locations at least two working days ...

  2. City Council Regular Meeting

    City Council | Calendar Event | 07/13/15 04:00pm

    created: 6/ 12/2015 In control: City Council Work Session On agenda: 7/ 13/2015 Final action: Title: ... Rapids Final Issued AML 12. 31. 14.pdf Grand Rapids Final Issued CAFR 12.31. 14.pdf Grand Rapids Final ... Issued LC Report 12. 31. 14. pdf Grand Rapids Final Issued IC Report 12. 31. 14.pdf 2. 15-1451 Hire ...

  3. 2023 City Electric Service Rate Schedule

    Public Utilities | Page

    2023 City Electric Service Rate Schedule- Adopted 12/14/2022 Image Slideshow Display Contact Info ... LIGHTING INDUSTRIAL $ $ $ $ $ Customer Charge (per month) 10.40 19.55 28.00 12.75 12.50 Adopted: ... Development 12/14/2022 01/01/2023 Minimum Bill Customer Charge Customer Charge Customer Charge Customer Charge ...

  4. Garages: One Story

    Community Development | Page

    must be attached with a minimum of 6d nails at 12 inches on center.  4X8 structural fiberboard ... 2-2X6 1 3-8 2-2X6 1 3-3 2-2X6 1 5-4 2-2X8 2 5-7 2-2X10 2 5-0 2-2X10 2 6-6 2-2X10 2 6-6 2-2X12 2 5-10 ... 2-2X12 2 7-6 2-2X12 2 7-0 3-2X10 2 6-4 3-2X10 2 6-8 3-2X8 2 8-2 3-2X12 2 7-4 3-2X12 2 8-2 3-2X10 2 8-2 ...

  5. 2023 City Water Rates

    Public Utilities | Page

    2023 City Water Rate Schedule- Adopted 12/14/2022 Image Slideshow Display Contact Info Block Web ... GRAND RAPIDS PUBLIC UTILITIES COMMISSION CITY WATER SERVICE RATE SCHEDULE Adopted: 12 ... $11.01 $3.94 $4.87 $6.22 $3.76 $4.64 Revised: Adopted 12/14/2022 Effective 01/01/2023 Last Revised: ...

  6. Gypsum Wallboard

    Community Development | Page

    rooms. 3. On ceilings where frame spacing exceeds 12 inches for ½ inch gypsum board and 16 inches for ... Board to Wood FramingNails a Screws 3/8”b Ceilingc Perpendicular 16 7 12 Nails: 13 gage, 1 ¼” long, ... Wall Either Direction 16 8 16 1/2 “ Ceilingc Either Direction 16 7 12 Nails: 13 gage, 1 ⅜” long, 19/64” ...

  7. 2023 City Electric Interim Annexation Areas Service Rate Schedule

    Public Utilities | Page

    2023 City Electric Interim Annexation Areas Service Rate Schedule- Adopted 12/14/2022 Image ... @ $0.1227/kWh 12/14/2022 01/01/2023 Minimum Bill Customer Charge Customer Charge PURCHASED POWER ADJUSTMENT ... 12/14/2022 Effective 01/01/2023 Last Revised: Adopted 12/15/2021 Effective 04/01/2022 Adopted 12 ...

  8. 2023 Electric Vehicle Service Rate Schedule

    Public Utilities | Page

    2023 Electric Vehicle Rate Schedule- Adopted 12/14/2022 Image Slideshow Display Contact Info Block ... kWh/mo@ $0.1612/kWh All kWh/mo @ $0.0550/kWh standalone charqe 12/14/2022 01/01/2023 Minimum Bill Customer ... 12/14/2022 Effective 01/01/2023 Last Revised: Adopted 12/15/2021 Effective 04/01/2022 Adopted 12 ...

  9. Footings, Foundations & Slabs

    Community Development | Page

    extend 12 inches below undisturbed ground (R403.1.4) The top surface of footings must be level. The ... Conventional light-frame construction 1-story 12 12 12 2-story 15 12 12 3-story 23 17 12 4-inch brick veneer ... over light frame or 8-inch hollow concrete masonry 1-story 12 12 12 2-story 21 16 12 3-story 32 24 16- ...

  10. 2023 Load Management Electric Service Rate Schedule

    Public Utilities | Page

    2023 Electric Load Management Rate Schedule- Adopted 12/14/2022 Image Slideshow Display Contact ... Monthly Credit 12/14/2022 01/01/2023 01/01/2023 All kWh/mo @ $0.0699/kWh Minimum bill- Customer Charge All ... Adopted 12/14/2022 Effective 01/01/2023 Last Revised: Adopted 12/15/2021 Effective 04/01/2022 Adopted ...

Pages