Garages: One Story
Community Development | Pagea garage are: Footing and foundation inspections after form work and reinforcement is in place but prior ... SIZES FOR GARAGES 20, 24, AND 28 FT WIDE 20 Ft WIDE 28 Ft WIDE 26 Ft WIDE Span Header Size # Jack Studs ... 2-2X12 2 7-6 2-2X12 2 7-0 3-2X10 2 6-4 3-2X10 2 6-8 3-2X8 2 8-2 3-2X12 2 7-4 3-2X12 2 8-2 3-2X10 2 8-2 ...
-
2023 City Multi-Family Water Rate Schedule
Public Utilities | Page24 25 90 over 90 4 $5.71 $3.99 $26.83 0 16 17 32 33 120 over 120 5 $5.71 $3.99 $32.54 0 20 21 40 41 ... 150 over 150 6 $5.71 $3.99 $38.25 0 24 25 48 49 180 over 180 7 $5.71 $3.99 $43.96 0 28 29 56 57 210 ... over 210 8 $5.71 $3.99 $49.67 0 32 33 64 65 240 over 240 9 $5.71 $3.99 $55.38 0 36 37 72 73 270 over ...
-
Special Assessments
Engineering / Public Works | Pagesuch properties. All developers shall be required to provide collateral in the form of cash, or ... R-4, and SR-4, shall be assessed 100% of a typical 32 foot wide urban residential street. See Appendix ... a typical 28 foot wide rural residential street. See Appendix “A” for typical construction items ...
-
Decks
Community Development | Page22 10 56 16 106 22 26 11 63 17 116 23 32 12 71 18 126 24 37 13 79 19 137 25 Required footing sizes ... CONNECTION DETAILS ON-CENTER SPACING OF FASTENERS4,5 ½” DIAM. LAG SCREW WITH 15/32” SHEATHING1 30 23 18 15 13 ... 11 10 ½” DIAM. BOLT WITH 15/32” MAX. SHEATHING 36 36 34 29 24 21 19 ½” DIAM. BOLT / 15/32” MAX. ...
-
Basic Wood Framing
Community Development | PageSUPPORTING SIZE BUILDING WIDTH (FT) 20 24 28 32 SPAN (JACK STUDS) SPAN (JACK STUDS) SPAN (JACK STUDS) SPAN ... attic assembly supported by 2 × 4 studs is limited to a roof span of 32 feet. Where the roof span ... exceeds 32 feet, the wall studs shall be increased to 2 × 6 or the studs shall be designed in accordance ...
-
Footings, Foundations & Slabs
Community Development | Pageprotected shallow foundations Insulating concrete form foundation walls SITE AND SOILS The area around any ... garage floor slabs 3,500c,d a. At 28 days psi. b. Concrete in these locations that may be subject to ... over light frame or 8-inch hollow concrete masonry 1-story 12 12 12 2-story 21 16 12 3-story 32 24 16- ...
-
Fasteners
Community Development | Pagediameter, 1 3/8” long, 7/32” head. Screws: Screws shall be Type S or W and penetrate into wood framing ... 1 5/8” long, 9/32” head. Screws: Screws shall be Type S or W and penetrate into wood framing a minimum of ... 6 12 19/32 – 1 8d common nail 6 12 1 1/8 – 1 ¼ 10d common nail or 8d deformed nail 6 12 a. All nails ...
-
Sample Project
Police | Projectlorem_ipsum.pdf Google Search Forms Aha Consulting 415 N State Street Lake Oswego, OR 97034 See map: Google Maps ...
-
2023 Electric Security Light Rates
Public Utilities | Page01/01/2023 Last Revised: Adopted 12/15/2021 Adopted 02/17/2021 Effective 04/01/2022 Effective 02/17/2021 ...
-
2021-2025 Amended Capital Improvement Plan
Finance | Page2021 2025thru Total2021 2022 2023 2024 2025 Category Source Airport Improvements 39,7501,750 28 ... 2021-2025 Amended Capital Improvement Plan Image Slideshow Display Contact Info Block Web Page ... Menu Settings 2021-2025 Amended Capital Improvement Plan Sort A to ...