Structural Engineers Reports
Administration | PageUBC, the snow load requirement for the Grand Rapids area was generally close to 30-35 psf and did not ... 53% compared to 30 psf as would be appropriate in the 1980s.) 4. The current required unbalanced ... 3. The 1980’s era roof trusses have a uniform snow load design capacity of approximately 30 psf. 4. ...
-
Roofing
Community Development | Pageoccur. Crickets or saddles are required on the ridge side of any chimney greater than 30 inches wide. ... FLASHING- 4- Cricket or Saddle required if chimney is more than 30 inches wide- 5- FASTENER SCHEDULE FOR ... Shakes must be interlaid with 18-inch-wide strips of No. 30 felt shingled between each course in such ...
-
Basic Wood Framing
Community Development | Page1-9 (1) 2-2X6 3-2 (2) 3-0 (2) 2-9 (2) 2-7 (2) 2-2X8 4-1 (2) 3-10 (2) 3-6 (2) 3-4 (2) 2-2X10 4-11 (2) ... 1 2-0 1 1-9 1 2-2×6 3-5 2 3-0 2 2-8 2 2-2×8 4-4 2 3-9 2 3-5 2 2-2×10 5-3 2 4-7 3 4-2 3 2-2×12 6-1 2 5-4 ...
-
Basement Finishing
Community Development | Pagea space at least 30 inches wide and at least 24 inches of clear space must be provided in front of the ... toilet. Showers should have a clear space within the stall of at least 30 inches. Fireplaces and ...
-
Decks
Community Development | Pageconnected to a structure), regardless of size, will not require permits if they are not more than 30 inches ... CONNECTION DETAILS ON-CENTER SPACING OF FASTENERS4,5 ½” DIAM. LAG SCREW WITH 15/32” SHEATHING1 30 23 18 15 13 ... decks more than 30” above grade. The height of the guard must be a minimum of 36”. Open guards must have ...
-
Temporary 3.2 Beer Sales and Service
Administration | PageThis is a Minnesota State issued license and will need approval at a Council meeting not less than 30 ...
-
Rental Housing Code
Community Development | PageShut Off Valves Cabinets / Countertops Fire Extinguisher (w/in 30’) Refrigerator Stove / Oven ...
-
Rental Housing Code
Community Development | PageShut Off Valves Cabinets / Countertops Fire Extinguisher (w/in 30’) Refrigerator Stove / Oven ...
-
Footings, Foundations & Slabs
Community Development | PageGM, GC, SM-SC & ML SC, MH, ML-CL & ICL 30 45 60 250 370 490 72 72 48 9’ 0” 8’ 4” GW, GP, SW ... and SP GM, GC, SM-SC & ML SC, MH, ML-CL & ICL 30 45 60 320 480 640 72 48 40 a. Sill plate ... of rebar or wire mesh. Rebar should be placed in a grid pattern with bars 30-36” apart.- 7- ...
-
Capital Improvements: Street Reconstruction Plan
Engineering / Public Works | Pagebituminous pavement placed. 12th Avenue SW will remain 30’ face to face and 10th Avenue SW will remain 37’ ...