Page not found
Search results
-
Site Plans
Community Development | PageDraw the site plan to the most appropriate scale, for example, 1" = 10’, 1" = 20’, 1/4" ... 30 Ft Lot Lines 60 Ft Street Right of Way Scale 1” = 10’ Existing Dwelling 38 Ft Wide X 20 Ft Deep ... Exst. 12X12 Shed Proposed New 12X24 Ft Garage Driveway Scale 1” = 10’ Proposed New Garage Existing ...
-
Economic Development Authority Regular Meeting
Economic Development Authority | Calendar Event | 02/08/18 04:00pm18 (with council term) Rick Blake— 12/ 31/ 18 (with council term) Mike Prcytarski — 3/ 1/ 21 Cory ... ALLOWED IN THE SUM OF: $ 1, 571. 65 TOTAL ALL DEPARTMENTS 21, 057. 55 NO 00 v a T n I> w CDH ' dO ...
-
Radon
Community Development | Pageleast 12 inches above the roof at least 10 feet from any window or other opening into conditioned spaces ... that is less than 2 feet below the exhaust point and at least 10 feet from any window or opening into ... an adjoining or adjacent building. 10) Active systems. If an active system is installed, the vent ...
-
Building Plans
Community Development | Pageetc.- 4- EXISTING DWELLING 16’ 6” 13’ PIN NEW FOOTING TO EXISTING CENTER PAD 24” X 24” 10” DEEP 8” x 20” ... Double Top Plate Manufactured Wood Trusses 24” o.c. 10 Inch by ½ Inch Anchor Bolts 6 Ft o.c., 12 inches ... ¾ Inch T&G Plywood over 2X10 Floor Joists, #2 Hem-Fir – 16” o.c. 2X6 Bottom Plate 2X6 Studs, 16” o.c. ...
-
Electric Distribution
Public Utilities | Pageprior to that date, a new customer of GRPU with a 15-minute peak of equal to or greater than 10 MW ... renewable generation capacity up to ten percent (10%) (non-cumulative) of the total GRPUC load, based on the ...
-
A look inside the Police Department
Police | News/Press Release | Jan 7, 2022into a city. It is home to over 10,000 people and the commercial hub of Itasca County. The population ... a calling. The department answered over 10,000 calls in 2017 and prided itself in providing professional, ...
-
Stairs & Guardrails
Community Development | Pagestairs, the width of the tread must be at least 10 inches at a point 12 inches from the side where the ... required at the top of an interior stair provided no door swings over the landing. 7 ¾ Inches Max 10 Inches ... through 7 ¾” Max rise 10” Min run Guard required if more than 30” 36” Min LANDINGS AT INTERIOR STAIRS ...
-
Commercial Utility Service Application
Public Utilities | Pagethe applicant(s), within seven days of connection, or services may be subject to disconnection. ... shall be in the form of cash, check, or money order. Deposits not received by the tenth business day ...
-
Ways to Support Your Library
Grand Rapids Area Library | Pageweekend of August annually during Tall Timber Days. It is generally held in the Central Square Mall. ...
-
Community Involvement
Engineering / Public Works | Pagetree planting days, volunteer monitoring programs, storm drain marking, or stream clean-up programs. ...